دورة الحياة
- نافذ
- آخر تعديل
Country / jurisdiction: Canada · Year: 2014 · Status: In force · Level: National · Type: Voluntary
This standard applies to single-phase electric room air conditioners that are not "packaged terminal air conditioners" and that do not exceed 10.55 kilowatts (36 000 Btu/h). With louvred sides, without reverse cycle:
-Less than 6 000 EER 9.7
-6 000 to 7 999 EER 9.7
-8 000 to 13 999 EER 9.8
-14 000 to 19 999 EER 9.7
-20 000 and over EER 8.5
With louvred sides, with reverse cycle:
-Less than 20 000 EER 9.0
- 20 000 or more EER 8.5
Without louvred sides, without reverse cycle:
-Less than 6 000 EER 9.0
-6000 to 7999 EER 9.0
-8 000 to 13 999 EER 8.5
-14 000 to 19 999 EER 8.5
-20 000 and over EER 8.5
Without louvred sides, with reverse cycle:
-less than 14 000 EER 8.5
-14 000 or more EER 8.0
Separate classes:
-Casement-only (all units) EER 8.7
-Casement-slider (all units) EER 9.5
* cooling capacity unit: Btu/h * EER unit: Btu/Wh
Official source: https://www.nrcan.gc.ca/energy-efficiency/energy-efficiency-regulations/guide-canadas-energy-efficiency/room-air-conditioners/6867
المصدر
https://www.iea.org/policies/2402الوثيقة الرسمية لدى الجهة التنظيمية. استشهد دائماً بهذا الرابط — لا بصفحة تفاصيل Vantage — في أدلة الامتثال.