INTIEAUnited States · IECC 2009 - Residential Code (Kentucky)PolicyIn force

IECC 2009 - Residential Code (Kentucky)

Governance Development Authority: International Code Commission and Kentucky Board of Housing, Buildings and Construction Implementation Authority: Local authorities Verification Authority: Code official Prescriptive Compliance path Occupiable space, excluding crawl spaces…

Dernière modification il y a 7 ans.

Vue extraite pour la lecture · Original pour les preuves de conformité

Cycle de vie

  1. En vigueur
  2. Dernière modification

Country / jurisdiction: United States · Year: 2014 · Status: In force · Level: State/Provincial · Type: Voluntary

Governance

Development Authority: International Code Commission and Kentucky Board of Housing, Buildings and Construction

Implementation Authority: Local authorities

Verification Authority: Code official

Prescriptive Compliance path

Occupiable space, excluding crawl spaces and garages

Energy Requirements:

Insulation

U-Values (Btu/h.ft2) Floor Roof Walls Windows

Climate zone 1 0.064 0.035 0.197 1.2

Climate zone 2 0.064 0.035 0.165 0.65

Climate zone 3A and 3B 0.047 0.035 0.141 0.5

Climate zone 4A and 4B 0.047 0.03 0.141 0.35

Climate zone 4C 0.033 0.03 0.082 0.35

Climate zone 5 0.033 0.03 0.082 0.35

Climate zone 6 0.033 0.026 0.06 0.35

Climate zone 7 0.033 0.026 0.057 0.35

Climate zone 8 0.028 0.026 0.057 0.35

Windows

The total glazed area may not exceed 18% of the conditioned floor area using the prescriptive method SHGC (for all fenestration including skylights) is 0.30 W/m2.k for climate zones 1-3. No SHGC requirement for other zones

Skylights

Skylights individually are 0.75 W/m2.k zones 1-2, 0.65 W/m2.k zone 3 and 0.60 W/m2.k zones 4-8

Air Leakage

7 ACH at 50Pa. The thermal envelope must be verified even when using the perscriptive method

Space Heating System

At least one thermostat shall be provided for each separate heating and cooling system. Specific requirements exist for ducts, piping, ventilation, pool systems and snow melt systems Requirements are relative to equipment size and building type.

Water Heating System

All circulating service hot water piping shall be insulated to at least R-2 and have automatic or accessible manual switches to turn off the pump when the system is not in use

Lighting

A minimum 50% of lamps in permanently installed lighting fixtures shall be high-efficacy lamps.

Renewable Energy

Pools deriving >60% heating energy from site-recovered or solar energy are exempt from pool specific energy saving measures

Compliance Softwares:

REScheck

End-uses considered:

Space cooling, Space heating, Water heating, Ventilation

Performance Compliance path

Not a requirement / performance based elements are based on a reference model and are relative to energy costs

Official source: https://www.energycodes.gov/adoption/states/kentucky

Source

https://www.iea.org/policies/7103

Document officiel chez le régulateur. Citez toujours cette URL — et non la page de détail Vantage — dans les preuves de conformité.

Connexes dans International

INTIEACanada · National Energy Code of Canada for BuildingsPolicyIn force

National Energy Code of Canada for Buildings

The National Energy Code of Canada for Buildings (NECB) 2025 is a national model code that sets technical requirements that address the protection of the environment in the design and construction of new buildings and in subsequent alterations. The 2025 edition was published in…

il y a 2 semaineseff.
INTIEACanada · Deep Retrofit Accelerator InitiativePolicyIn force

Deep Retrofit Accelerator Initiative

Launched by Natural Resource Canada in February 2023, the Deep Retrofit Accelerator Initiative (DRAI) provides funding to organisations and projects that facilitate the development of deep retrofits in commercial, institutional, and mid- or high-rise multi-unit residential…

il y a 2 semaineseff.
INTIEASweden · Tax exemption for pure and highblend biofuelsPolicyIn force

Tax exemption for pure and highblend biofuels

The Swedish scheme to promote the use of sustainable biofuels in transport has been prolongated until 31 December 2032 with an estimated budget of 1.3 USD billion (SEK 14.2 billion).    The scheme was originally approved by the Commission in November 2003 and prolonged several…

il y a 2 semaineseff.
INTIEACanada · Codes Acceleration Fund (CAF)PolicyIn force

Codes Acceleration Fund (CAF)

Launched by Natural Resource Canada in 2023,  the Codes Acceleration Fund (CAF) provides funding to support efforts to accelerate and contribute to code (or regulation) adoption, compliance and enforcement. The programme provides funding to:   • provinces, territories,…

il y a 2 semaineseff.
INTIEACanada · Energy Efficiency Regulations, 2016 - Electric motorsPolicyIn force

Energy Efficiency Regulations, 2016 - Electric motors

The Energy Efficiency Regulations set standards for several industrial products and industrial applications of products including motors, air compressors, pumps, dry-type transformers and ceiling fans.     The standards for electric motors were regularly updated, lastly in 2022…

il y a 2 semaineseff.