Country / jurisdiction: Indonesia · Year: 2015 · Status: In force · Level: National · Type: Voluntary
The labelling for ballasted lamps has been effective since June 2015, or, 12 months after the Ministerial Regulation No. 18/2014 was enacted. It has been designed to provide information about the lighting quality to the public by showing 4-star comparative labelling. Ballasts are categorised as warmlight (<4400K) and cool daylight (>=4400K)
Efficiency Units on lumens/watt
For < 8 W
1-star: <34 (warm), <33 (cool)
2-star: >=34 (warm), >=33 (cool)
3-star: >=44 (warm), >=42 (cool)
4-star: >=54 (warm), >=51 (cool)
For > 8 - 15 W
1-star: <38 (warm), <37 (cool)
2-star: >=38 (warm), >=37 (cool)
3-star: >=48 (warm), >=46 (cool)
4-star: >=58 (warm), >=55 (cool)
For >15 - 25 W
1-star: <42 (warm), <41 (cool)
2-star: >=42 (warm), >=41 (cool)
3-star: >=52 (warm), >=50 (cool)
4-star: >=62 (warm), >=59 (cool)
For >25 - 60 W
1-star: <46 (warm), <45 (cool)
2-star: >=46 (warm), >=45 (cool)
3-star: >=56 (warm), >=54 (cool)
4-star: >=66 (warm), >=63 (cool)
Official source: https://jdih.esdm.go.id/peraturan/Permen%20ESDM%2018%20Tahun%202014.pdf