INTIEANorway · The Planning and Building Act (2010-2015)PolicyIn force

The Planning and Building Act (2010-2015)

Applicable Building Type(s) Existing residential, New residential, New non-residential, Existing non-residential Policy Requirement Level Mandatory Governance Development Authority: Norwegian Building Authority, Ministry of Local Government and Modernisation Implementation…

Dernière modification il y a 9 ans.

Vue extraite pour la lecture · Original pour les preuves de conformité

Cycle de vie

  1. En vigueur
  2. Dernière modification

Country / jurisdiction: Norway · Year: 2010 · Status: In force · Level: National · Type: Voluntary

Applicable Building Type(s) Existing residential, New residential, New non-residential, Existing non-residential Policy Requirement Level Mandatory Governance Development Authority: Norwegian Building Authority, Ministry of Local Government and Modernisation Implementation Authority: Local Authorities Verification Authority: Local Authorities Enforcement Authority: Local Authorities Prescriptive Compliance path Heated usable floor area Energy Requirements: Insulation U-Values (W/m2.K) Walls Floor Roof Minimum requirements â €° ¤ 0.22 â €° ¤ 0.18 â €° ¤ 0.18 Basic/standard requirements â €° ¤ 0.18 â €° ¤ 0.15 â €° ¤ 0.12 Windows U-Values (W/m2.K) Windows Minimum requirements â €° ¤ 1.6 Basic/standard requirements â €° ¤ 1.2 The total sun factor for glass/windows (gt) shall be less than 0.15 on faà §ades that catch the sun (not applicable for small houses). Proportion of window and door areas â €° ¤ 20% of heated usable floor space. The U-value for the glass/windows/doors including the frames shall be less than 0.24 when multiplied by the proportion of the window and door areas of the buildings heated usable floor area (not applicable for small houses). Air Leakage Small houses and leisure homes with more than 150 m2 of heated usable floor space 2.5 l/(s.m2) at 50 Pa Space Heating System Specific Fan Power (kW/m3/s) Specific fan power All climate zones 2.5 Renewable Energy Buildings > 500m2 shall be designed and constructed so that a minimum of 60% of the net energy need for space and water heating may be met by energy supply other than direct acting electricity or fossil fuels. For buildings < 500m2 the requirement is a a mimimum of 40 % other than direct acting electricity or fossil fuels. Compliance Softwares: Various software can be used if in line with national calculation methods End-uses considered: Appliances, Space heating, Water heating, Lighting interior, Ventilation Performance Compliance path Small houses and leisure homes with more than 150 m2 of heated usable floor space 120 kWh/m2/year + 1600 kWh/m2 of heated usable floor area Block of flats 115 kWh/m2/year Resources Notes Climate zones

Official source: http://www.iea.org/beep/Norway/

Source

https://www.iea.org/policies/2536

Document officiel chez le régulateur. Citez toujours cette URL — et non la page de détail Vantage — dans les preuves de conformité.

Connexes dans International

INTEnergy Newsoilprice:oilprice-article-44766ActualitésIn force

The Billion-Dollar Debt Deals Exposing an Oil Giant

Last week, Angola&#039;s state oil company, Sociedade Nacional de Combustíveis de Angola (Sonangol), secured a $2.65-billion financing deal with a consortium of international banks to fund the company&#039;s operating expenses and capital investments. The financing was heavily backed by a syndicate of foreign lenders including Société Générale, First Abu Dhabi Bank, Standard Bank of South Africa and Absa, while local Angolan banks, including Banco Fomento de Angola (BFA), Banco Millennium Atlântico and Banco Angolano…

il y a 7 heures
INTEnergy Newsoilprice:oilprice-article-44770ActualitésIn force

AI Demand, War, and Climate Pressure Push World Back To Nuclear

Global energy markets are in turmoil as energy crises keep piling up. The energy-hungry AI boom, war in Iran, geopolitical instability, and climate pressures are creating a polycrisis for the global energy sector, and it’s just getting started. To solve multiple overlapping crises, we will need multiple overlapping solutions. An all-of-the-above solution to increasing energy security is therefore gaining favor on a global scale as the precariousness of over-reliance on limited energy supply chains becomes dangerously clear. While fossil fuels…

il y a 9 heures
INTEnergy Newsrigzone:https://www.rigzone.com/news/wire/uk_grid_issues_another_supply_warning-26-jun-2026-184002-article/?rss=trueActualitésIn force

UK Grid Issues Another Supply Warning

The UK grid operator issued a second power supply warning for Friday evening.

il y a 9 heures
INTEnergy Newsrigzone:https://www.rigzone.com/news/wire/crude_falls_on_rising_gulf_supplies-26-jun-2026-184005-article/?rss=trueActualitésIn force

Crude Falls On Rising Gulf Supplies

Oil prices fell sharply as rising Strait of Hormuz traffic and increasing Persian Gulf exports fueled oversupply concerns.

il y a 9 heures
INTEnergy Newsoilprice:oilprice-article-44772ActualitésIn force

China&#039;s Battery Giant Bets Big on Sodium as Lithium Volatility Persists

The world’s largest battery maker is taking a step back from the eclectic vehicles sector to refocus its efforts on energy storage. China’s Contemporary Amperex Technology Co. Ltd. (better known as CATL) has been building up its energy storage portfolio for years now, but the company’s transition away from EVs and toward energy systems has been supercharged by the artificial intelligence boom. Five years ago, just 2 percent of CATL’S sales came from battery storage. Today, storage accounts for a full quarter of the megacompany’s…

il y a 10 heures