Cycle de vie
- En vigueur
- Dernière modification
Country / jurisdiction: People's Republic of China · Year: 2015 · Status: In force · Level: National · Type: Voluntary
MEPS for electric water chiller with vapor compression cycle. Energy performance, here indicated through Integrated Part Load Value (IPLV) for different capacity ranges are:
air-cooled or evaporating cooled
CC = 50 kW: COP 2.50, IPLV 2.80;
CC > 50 kW: COP 2.70, IPLV 2.90; water-cooled:
water-cooled
CC = 528 kW: COP 4.20, IPLV 5.00;
528 kW < CC = 1163 kW: COP4.70, IPLV 5.50;
CC > 1163 kW: COP 5.20, IPLV 5.90
IPLV = Integrated Part Load Value
CC = Cooling capacity
COP= Coefficient of Performance
Official source: http://www.cssn.net.cn/cssn/front/83148253.html