Country / jurisdiction: Uganda · Year: 2011 · Status: In force · Level: National · Type: Voluntary
Minimum Energy Performance Standard (MEPS) requirements for double-capped tubular fluorescent lamps with a nominal length of 550 mm to 1500 mm and having nominal lamp wattage of 16 watts or more.
This standard covers lamps for general illumination purposes, for use in luminaires and with lamp ballasts connected to a 240 V 50 Hz single phase or similar mains supply. Lamps that are intended for use only with high frequency (electronic) ballasts are also covered.
Lamp efficacy requirements:
Lamp nominal length: 550 < L < 700
Lamp typical power: 16 - 24
Initial efficacy: F 100 > 66.0 and FM > 57.5
Minimum CRI: 79
Lamp nominal length: 700 < L < 1150
Lamp typical power: 17 - 40
Initial efficacy: F 100 > 74.0 and FM > 61.0
Minimum CRI: 79
Lamp nominal length: 1150 < L < 1350
Lamp typical power: 28 - 50
Initial efficacy: F 100 > 80.0 and FM > 70.0
Minimum CRI: 79
Lamp nominal length: 1350 < L < 1500
Lamp typical power: 35 - 80
Initial efficacy: F 100 > 85.0 and FM > 70.0
Minimum CRI: 79
Official source: http://www.puntofocal.gov.ar/notific_otros_miembros/uga210_t.pdf