INTIEAUnited States · 2009 IECC State Residential building Code (West Virginia)PolicyIn force

2009 IECC State Residential building Code (West Virginia)

Notable requirements in the 2009 IECC: · Building envelope must be caulked and sealed. · Slab-on-grade insulation is R-10 to a depth of 2 feet. · Supply ducts in attics must be insulated to R-8. Return ducts in attics and all ducts in crawlspaces, unheated basements, garages, or…

Last changed 7 years ago.

Extracted view for reading · Original for compliance evidence

Lifecycle

  1. Effective
  2. Last change

Country / jurisdiction: United States · Year: 2013 · Status: In force · Level: State/Provincial · Type: Voluntary

Notable requirements in the 2009 IECC:

· Building envelope must be caulked and sealed.

· Slab-on-grade insulation is R-10 to a depth of 2 feet.

· Supply ducts in attics must be insulated to R-8. Return ducts in attics and all ducts in crawlspaces,

unheated basements, garages, or otherwise outside building envelope must be insulated to R-6.

· All ducts must be sealed and either:

o verified by pressure testing – the duct system has to be tested and the air leakage out of ducts must be kept to an acceptable maximum level.

o installed entirely within the building thermal envelope – testing is not required if all ducts are inside the building thermal envelope (for example in heated basements), though the ducts still have to be sealed.

· Piping for hydronic (boiler) heating systems must be insulated to R-3.

· Although vapor retarders are not required by the IECC, the I-codes do set wall vapor retarder requirements in Section R601.3 of the 2009 IRC, and vapor retarders are required in Zone 5.

· Less insulation is allowed for mass walls and more insulation is required for steel framing.

· 50% of the lighting “lamps” (bulbs, tubes, etc.) in a building must be high efficacy. Compact fluorescents qualify, standard incandescent bulbs do not.

· Standard I-code administrative requirements (inspections, documentation) apply.

· A certificate must be posted near the electrical panel listing insulation levels and other energy efficiency measures.

2009 IECC:

Policy Requirement Level

Model Code

Governance

Development Authority: International Code Council

Implementation Authority: Local authorities

Prescriptive Compliance path

Occupiable space, excluding crawl spaces and garages

Energy Requirements:

Insulation

U-Values (Btu/h.ft2) Floor Roof Walls

Climate zone 1 0.064 0.035 0.197

Climate zone 2 0.064 0.035 0.165

Climate zone 3A and 3B 0.047 0.035 0.141

Climate zone 4A and 4B 0.047 0.03 0.141

Climate zone 4C 0.033 0.03 0.082

Climate zone 5 0.033 0.03 0.082

Climate zone 6 0.033 0.026 0.06

Climate zone 7 0.033 0.026 0.057

Climate zone 8 0.028 0.026 0.057

Windows

U-Values (Btu/h.ft2) Windows

Climate zone 1 1.2

Climate zone 2 0.65

Climate zone 3A and 3B 0.5

Climate zone 4A and 4B 0.35

Climate zone 4C 0.35

Climate zone 5 0.35

Climate zone 6 0.35

Climate zone 7 0.35

Climate zone 8 0.35

The total glazed area may not exceed 18% of the conditioned floor area using the prescriptive method

SHGC (for all fenestration including skylights) is 0.30 W/m2.k for climate zones 1-3. No SHGC requirement for other zones

Skylights

Skylights individually are 0.75 W/m2.k zones 1-2, 0.65 W/m2.k zone 3 and 0.60 W/m2.k zones 4-8

Air Leakage

7 ACH at 50Pa. The thermal envelope must be verified even when using the perscriptive method

Space Heating System

At least one thermostat shall be provided for each separate heating and cooling system.

Specific requirements exist for ducts, piping, ventilation, pool systems and snow melt systems

Requirements are relative to equipment size and building type.

Water Heating System

All circulating service hot water piping shall be insulated to at least R-2 and have automatic or accessible manual switches to turn off the pump when the system is not in use

Lighting

A minimum 50% of lamps in permanently installed lighting fixtures shall be high-efficacy lamps.

Renewable Energy

Pools deriving >60% heating energy from site-recovered or solar energy are exempt from pool specific energy saving measures

End-uses considered:

Space cooling, Space heating, Water heating, Ventilation, Lighting interior, Lighting exterior

Performance Compliance path

Not a requirement / performance based elements are based on a reference model and are relative to energy costs

End-uses considered:

Water heating, Ventilation, Space heating, Space cooling, Lighting interior, Equipment

Resources

Notes

Climate zones

ZONE

NUMBER

THERMAL CRITERIA

IP Un

Official source: https://www.energycodes.gov/sites/default/files/documents/Residential_West_Virginia_0.pdf

Source

https://www.iea.org/policies/7143

Canonical document at the regulator. Always cite this URL — not the Vantage detail page — in compliance evidence.

Related in International

INTEnergy Newsoilprice:oilprice-article-45056NewsIn force

The U.S. Army Just Called China’s Bluff in the Rare Earth War

Just recently, in a span of about six weeks, one impressive company was selected by the U.S. Army to build and operate rare earth processing facilities on an American military base…the first time the Army has ever done this. That same company closed $100 million in institutional financing, giving it a war chest of roughly $130 million. It was also formally added to the Russell 3000 Index. And it locked in MOU’s for feedstock agreements covering billions of tonnes of rare earth-bearing material from sources across Wyoming, Appalachia…

14 hours ago
INTEnergy Newsoilprice:oilprice-article-45052NewsIn force

Oil Prices Ignore the Warning Signs in Physical Markets

Oil price movements since the start of March this year have become the topic of dozens of discussions. Many have been puzzled by futures prices and why they haven’t gone through the roof given the severe disruption in Middle Eastern supply. It appears the reason is sheer optimism and a bet on market adaptability. However, there is a problem with that. Adaptability has limits. Many commentators like to compare the current oil price—and supply—situation to 2022, when Russia’s incursion into eastern Ukraine prompted an actual…

15 hours ago
INTEnergy Newsoilprice:oilprice-article-45054NewsIn force

The World’s Largest Sand Battery Is Now Online

Modern power grids require a constant, real-time balance between supply and consumption. Unfortunately, the integration of wind and solar energy makes power grids unstable due to the intermittent nature of renewable energy generation. To prevent localized grid blackouts or harmful voltage spikes, utilities are increasingly pairing renewables with battery storage and/or rapid-response natural gas plants to smooth out fluctuating supply. However, Finland has now come up with a rather eccentric method to store excess renewable energy and release it…

16 hours ago
INTEnergy Newsrigzone:https://www.rigzone.com/news/wire/australia_to_study_first_new_oil_refinery_since_60s-28-jul-2026-184235-article/?rss=trueNewsIn force

Australia to Study First New Oil Refinery Since 60s

Prime Minister Anthony Albanese Tuesday announced a study for a new refinery in Karratha in Western Australia, backed by A$4 million ($2.8 million) of government funds.

17 hours ago
INTEnergy Newsoilprice:oilprice-article-45055NewsIn force

Refined Fuels, Not Crude, Are Driving the Oil Market Crunch

Oil prices have just come off a fresh two-month high as the crude oil market has tumbled this week amid signals of de-escalation in the U.S.-Iran conflict. Despite the slump in crude prices and the extreme volatility in the past five months, the refined product market continues to tighten with refining margins at record highs because the supply of petroleum products is much tighter than crude supply. Refining margins held at record highs even as crude oil prices soared last week to $100 per barrel. That’s because global gasoline, diesel,…

17 hours ago