Country / jurisdiction: Chinese Taipei · Year: 2002 · Status: In force · Level: National · Type: Voluntary
This standard defines minimum energy efficiency ratio of window type air conditioners with power capacity less than 3 kW.
Unitary (old CNS 3615)
CC Less than 2,000Kcal/h: EER 2.33 (9.24)
CC above 2,000 Kcal/h and below 3,550Kcal/h: EER (kcal/h-W) 2.38 EER(BTU/h-W) 9.44
CC above 3550 Kcal/h: EER (kcal/h-W) 2.24 EER(BTU/h-W) 8.89
Unitary (new CNS3615 and CNS14464)
CC Less than 2.3 kW: EER (W/W) 2.71
CC between 2.3 kW and 4.1 Kw: EER (W/W) 2.77
CC above 4.1 kW: EER (W/W) 2.60
Split (old CNS 3615)
below 3,550Kcal/h:
fixed speed: EER 2.55(10.12)
variable speed: EER 2.38(9.44)
above 3550 Kcal/h: EER 2.35(9.32)
Split (new CNS3615 and CNS14464) :
below 4.1 kW:
fixed speed: EER 2.97
variable speed: EER 2.77
above 4.1 kW: EER 2.73