Lifecycle
- Effective
- Last change
Country / jurisdiction: United Kingdom · Year: 2010 · Status: In force · Level: National · Type: Voluntary
Applicable Building Type(s) New residential Policy Requirement Level Mandatory Governance Development Authority: Department of Finance and Personnel Implementation Authority: Local Authority Verification Authority: Local Authority Enforcement Authority: Local Authority Prescriptive Compliance path Energy Requirements: Insulation U-Values (W/m2.K) Walls Floor Roof All climate zones 0.35 0.25 0.25 Windows U-Values (W/m2.K) Windows All climate zones 2.2 Air Leakage 10 m3/(h.m2) at 50 Pa Compliance Softwares: SAP (Standardised Assessment Procedure) 2009 End-uses considered: Space heating, Water heating, Lighting interior, Ventilation Performance Compliance path CO2 emissions against a notional dwelling Resources Notes Climate zones
Official source: http://www.legislation.gov.uk/uksi/2010/2214/contents/made
Source
https://www.iea.org/policies/2037Canonical document at the regulator. Always cite this URL — not the Vantage detail page — in compliance evidence.