This regulation establishes FDA standards for diagnostic radiopharmaceuticals used in vivo for diagnostic and monitoring purposes. It defines diagnostic radiopharmaceuticals, outlines safety and effectiveness evaluation criteria including pharmacological/toxicological activity and absorbed radiation dose, categorizes proposed indications (structure delineation, functional assessment, disease detection, patient management), and specifies methods for demonstrating effectiveness through clinical evaluation against reliable diagnostic standards.

آخر تعديل قبل شهر واحد.

العرض المستخرج للقراءة · النص الأصلي للأدلة الامتثالية

PART 315—DIAGNOSTIC RADIOPHARMACEUTICALS

§ 315.1 Scope.

The regulations in this part apply to radiopharmaceuticals intended for in vivo administration for diagnostic and monitoring use. They do not apply to radiopharmaceuticals intended for therapeutic purposes. In situations where a particular radiopharmaceutical is proposed for both diagnostic and therapeutic uses, the radiopharmaceutical must be evaluated taking into account each intended use.

§ 315.2 Definition.

For purposes of this part, diagnostic radiopharmaceutical means:

(a) An article that is intended for use in the diagnosis or monitoring of a disease or a manifestation of a disease in humans and that exhibits spontaneous disintegration of unstable nuclei with the emission of nuclear particles or photons; or

(b) Any nonradioactive reagent kit or nuclide generator that is intended to be used in the preparation of such article as defined in paragraph (a) of this section.

§ 315.3 General factors relevant to safety and effectiveness.

FDA's determination of the safety and effectiveness of a diagnostic radiopharmaceutical includes consideration of the following:

(a) The proposed use of the diagnostic radiopharmaceutical in the practice of medicine,

(b) The pharmacological and toxicological activity of the diagnostic radiopharmaceutical (including any carrier or ligand component of the diagnostic radiopharmaceutical), and

(c) The estimated absorbed radiation dose of the diagnostic radiopharmaceutical.

§ 315.4 Indications.

(a) For diagnostic radiopharmaceuticals, the categories of proposed indications for use include, but are not limited to, the following:

(1) Structure delineation;

(2) Functional, physiological, or biochemical assessment;

(3) Disease or pathology detection or assessment; and

(4) Diagnostic or therapeutic patient management.

(b) Where a diagnostic radiopharmaceutical is not intended to provide disease-specific information, the proposed indications for use may refer to a biochemical, physiological, anatomical, or pathological process or to more than one disease or condition.

§ 315.5 Evaluation of effectiveness.

(a) The effectiveness of a diagnostic radiopharmaceutical is assessed by evaluating its ability to provide useful clinical information related to its proposed indications for use. The method of this evaluation varies depending upon the proposed indication(s) and may use one or more of the following criteria:

(1) The claim of structure delineation is established by demonstrating in a defined clinical setting the ability to locate anatomical structures and to characterize their anatomy.

(2) The claim of functional, physiological, or biochemical assessment is established by demonstrating in a defined clinical setting reliable measurement of function(s) or physiological, biochemical, or molecular process(es).

(3) The claim of disease or pathology detection or assessment is established by demonstrating in a defined clinical setting that the diagnostic radiopharmaceutical has sufficient accuracy in identifying or characterizing the disease or pathology.

(4) The claim of diagnostic or therapeutic patient management is established by demonstrating in a defined clinical setting that the test is useful in diagnostic or therapeutic patient management.

(5) For a claim that does not fall within the indication categories identified in § 315.4, the applicant or sponsor should consult FDA on how to establish the effectiveness of the diagnostic radiopharmaceutical for the claim.

(b) The accuracy and usefulness of the diagnostic information is determined by comparison with a reliable assessment of actual clinical status. A reliable assessment of actual clinical status may be provided by a diagnostic standard or standards of demonstrated accuracy. In the absence of such diagnostic standard(s), the actual clinical status must be established in another manner, e.g., patient followup.

§ 315.6 Evaluation of safety.

(a) Factors considered in the safety assessment of a diagnostic radiopharmaceutical include, among others, the following:

(1) The radiation dose;

(2) The pharmacology and toxicology of the radiopharmaceutical, including any radionuclide, carrier, or ligand;

(3) The risks of an incorrect diagnostic determination;

(4) The adverse reaction profile of the drug;

(5) Results of human experience with the radiopharmaceutical for other uses; and

(6) Results of any previous human experience with the carrier or ligand of the radiopharmaceutical when the same chemical entity as the carrier or ligand has been used in a previously studied product.

(b) The assessment of the adverse reaction profile includes, but is not limited to, an evaluation of the potential of the diagnostic radiopharmaceutical, including the carrier or ligand, to elicit the following:

(1) Allergic or hypersensitivity responses,

(2) Immunologic responses,

(3) Changes in the physiologic or biochemical function of the target and nontarget tissues, and

(4) Clinically detectable signs or symptoms.

(c)(1) To establish the safety of a diagnostic radiopharmaceutical, FDA may require, among other information, the following types of data:

(i) Pharmacology data,

(ii) Toxicology data,

(iii) Clinical adverse event data, and

(iv) Radiation safety assessment.

(2) The amount of new safety data required will depend on the characteristics of the product and available information regarding the safety of the diagnostic radiopharmaceutical, and its carrier or ligand, obtained from other studies and uses. Such information may include, but is not limited to, the dose, route of administration, frequency of use, half-life of the ligand or carrier, half-life of the radionuclide, and results of clinical and preclinical studies. FDA will establish categories of diagnostic radiopharmaceuticals based on defined characteristics relevant to risk and will specify the amount and type of safety data that are appropriate for each category (e.g., required safety data may be limited for diagnostic radiopharmaceuticals with a well established, low-risk profile). Upon reviewing the relevant product characteristics and safety information, FDA will place each diagnostic radiopharmaceutical into the appropriate safety risk category.

(d) Radiation safety assessment. The radiation safety assessment must establish the radiation dose of a diagnostic radiopharmaceutical by radiation dosimetry evaluations in humans and appropriate animal models. The maximum tolerated dose need not be established.

المصدر

https://www.ecfr.gov/current/title-21/part-315

الوثيقة الرسمية لدى الجهة التنظيمية. استشهد دائماً بهذا الرابط — لا بصفحة تفاصيل Vantage — في أدلة الامتثال.

ذات صلة في United States

US10 CFR10 CFR Part 20Secondary legislationIn force

Standards for Protection Against Radiation

10 CFR Part 20 establishes federal standards for protection against ionizing radiation from NRC-licensed activities. It sets dose limits for individuals exposed to byproduct, source, and special nuclear materials, defines key radiation protection terms (absorbed dose, airborne radioactivity, ALARA), and applies to licensees under parts 30–72 of the CFR. Medical exposures and background radiation are excluded.

قبل 4 ساعات
US10 CFR10 CFR Part 36Secondary legislationIn force

Licenses and Radiation Safety Requirements for Irradiators

10 CFR Part 36 establishes licensing and radiation safety requirements for panoramic and underwater irradiators using sealed radioactive sources for gamma irradiation, with dose rates exceeding 5 grays per hour at 1 meter. The regulations exempt self-contained dry-source-storage irradiators, medical, radiography, gauging, and agricultural applications. Licensees must comply with additional federal, state, and local regulations on facility siting, zoning, and building codes.

قبل 4 ساعات
US10 CFR10 CFR Part 835Secondary legislationIn force

Occupational Radiation Protection

10 CFR Part 835 establishes occupational radiation protection standards and limits for DOE activities to protect workers from ionizing radiation. The regulation defines scope, exclusions (NRC-licensed activities, naval reactors, medical uses, foreign territory operations), and requires compliance with occupational dose limits. Key concepts include accountable sealed sources, airborne radioactivity, and ALARA principles for minimizing radiation exposure.

قبل 4 ساعات
US10 CFR10 CFR Part 39Secondary legislationIn force

Licenses and Radiation Safety Requirements for Well Logging

10 CFR Part 39 establishes licensing and radiation safety requirements for the use of licensed materials—including sealed sources, radioactive tracers, markers, and uranium sinker bars—in well logging operations. The regulation prescribes definitions, operational requirements, supervisory standards, and compliance obligations for persons handling radioactive sources at temporary jobsites, including personal supervision, safety reviews, and cross-referenced NRC regulatory provisions.

قبل 4 ساعات
US10 CFR10 CFR Part 34Secondary legislationIn force

Licenses for Industrial Radiography and Radiation Safety Requirements for Industrial Radiographic Operations

10 CFR Part 34 prescribes licensing and radiation safety requirements for industrial radiography operations using sealed sources of byproduct material. The rule mandates adherence to ALARA principles to minimize radiation exposure, requires annual refresher safety training for employees, and defines standards for radiographic equipment including exposure devices, guide tubes, and collimators. Requirements apply to all industrial radiography users but exclude medical applications.

قبل 4 ساعات